新闻动态

新闻中心

博士生胡俊伟在Applied Thermal Engineering发表论文

2006-06-12

Junwei Hu, Guoliang Ding. Effect of the air outlet louver on the noise generated by the outdoor set of a split-unit air conditioner. Applied Thermal Engineering, 2006, 26: 1735-1745

Abstract
In order to analyze the influence of the air outlet louver on the noise generated by the outdoor set of a split-unit air conditioner, the flow field in the outdoor set is simulated with the CFD software STAR-CD. The relative turbulent intensities are computed and the influence of the shape and the steel wire diameter of the air outlet louver on the noise generated by the outdoor set is analyzed. The results of computation and experiment show that the circular shape of air outlet louver give benefit of noise decrease. An air outlet louver with different diameters of steel wires is designed on the basis of analysis of the influence of the steel wire diameter of the air outlet louver on the noise. The computation and experiment validate that the air outlet louver with different diameters of steel wires can improve the aerodynamic performance and reduce the noise generated by the outdoor set.
Keywords: Air outlet louver; Outdoor set;  Air conditioner; Simulation; Relative turbulent intensity